Fuji Electric FRENIC‑Multi Error erf: Software Error

Variable frequency drive · taken from the manufacturer’s manual, pages cited

Error codeerf

Software Error occurs when the interface printed circuit board is not installed properly, control printed circuit board capacity setting is incorrect, or there is an abnormal connection between printed circuit boards. The manual's first action is: “Remove interface printed circuit board and reinsert until "click" sound is heard.”

Model
Fuji Electric FRENIC‑Multi
Display shows
Software Error (erf)
Type
Error code
Source
Manual p. 158

What erf means

Software Error p. 158

Common causes

  • (1) Interface printed circuit board not installed properly p. 158
  • (2) Control printed circuit board capacity setting incorrect p. 158
  • (3) Abnormal connection between control printed circuit board, power printed circuit board, power printed circuit board, and interface printed circuit board p. 158
  • (4) Abnormal connection between control printed circuit board and optional printed circuit board p. 158

What to do

  1. Remove interface printed circuit board and reinsert until "click" sound is heard. p. 158
  2. Re-set inverter capacity. p. 158
  3. Replace control printed circuit board, power printed circuit board, or interface printed circuit board. p. 158

Before you service the product, read the safety instructions in the manual p. 3.

If erf is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Fuji Electric service.

This page summarises what the manufacturer’s manual says about erf; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fuji Electric. Found a mistake? Report an error.