Software Error occurs when the interface printed circuit board is not installed properly, control printed circuit board capacity setting is incorrect, or there is an abnormal connection between printed circuit boards. The manual's first action is: “Remove interface printed circuit board and reinsert until "click" sound is heard.”
- Model
- Fuji Electric FRENIC‑Multi
- Display shows
- Software Error (erf)
- Type
- Error code
- Source
- Manual p. 158
What erf means
Software Error p. 158
Common causes
- (1) Interface printed circuit board not installed properly p. 158
- (2) Control printed circuit board capacity setting incorrect p. 158
- (3) Abnormal connection between control printed circuit board, power printed circuit board, power printed circuit board, and interface printed circuit board p. 158
- (4) Abnormal connection between control printed circuit board and optional printed circuit board p. 158
What to do
- Remove interface printed circuit board and reinsert until "click" sound is heard. p. 158
- Re-set inverter capacity. p. 158
- Replace control printed circuit board, power printed circuit board, or interface printed circuit board. p. 158
Before you service the product, read the safety instructions in the manual p. 3.
If erf is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Fuji Electric service.
This page summarises what the manufacturer’s manual says about erf; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fuji Electric. Found a mistake? Report an error.