Fagor Servo Drive System Error 608: Feedback signal warning: attenuation of motor feedback A and/or B signal is too large.

Fagor Servo Drive System · taken from the manufacturer’s manual, pages cited

Warning code608

Code 608 means the feedback signal warning indicates that the attenuation of motor feedback A and/or B signal is too large due to parameters RP1, RP2, RP3, or RP4 being too small. The manual's first action is: “Check the cable, feedback device, and X4 card status, or increase the values of these parameters.”

Model
Fagor Servo Drive System
Display shows
608
Type
Warning code
Source
Manual p. 551

What 608 means

Feedback signal warning: attenuation of motor feedback A and/or B signal is too large. p. 551

Common causes

  • Parameters RP1, RP2, RP3, or RP4 are too small. p. 551

What to do

  1. Check the cable, feedback device, and X4 card status, or increase the values of these parameters. p. 551

Before you service the product, read the safety instructions in the manual p. 444.

If 608 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Fagor service.

This page summarises what the manufacturer’s manual says about 608; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fagor. Found a mistake? Report an error.