Code 608 means the feedback signal warning indicates that the attenuation of motor feedback A and/or B signal is too large due to parameters RP1, RP2, RP3, or RP4 being too small. The manual's first action is: “Check the cable, feedback device, and X4 card status, or increase the values of these parameters.”
- Model
- Fagor Servo Drive System
- Display shows
- 608
- Type
- Warning code
- Source
- Manual p. 551
What 608 means
Feedback signal warning: attenuation of motor feedback A and/or B signal is too large. p. 551
Common causes
- Parameters RP1, RP2, RP3, or RP4 are too small. p. 551
What to do
- Check the cable, feedback device, and X4 card status, or increase the values of these parameters. p. 551
Before you service the product, read the safety instructions in the manual p. 444.
If 608 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Fagor service.
This page summarises what the manufacturer’s manual says about 608; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fagor. Found a mistake? Report an error.