Code 607 means the direct feedback signal A and/or B value is saturated due to a faulty cable, feedback device, or feedback board (connector X4 or X3). The manual's first action is: “Check the cable, feedback device, card, or reduce the values of these parameters.”
- Model
- Fagor Servo Drive System
- Display shows
- Direct feedback signal A and/or B value saturated. (607)
- Type
- Fault code
- Source
- Manual p. 551
What 607 means
Direct feedback signal A and/or B value saturated. p. 551
Common causes
- Cable, feedback device, or feedback board (connector X4 or X3) is faulty. p. 551
What to do
- Check the cable, feedback device, card, or reduce the values of these parameters. p. 551
Before you service the product, read the safety instructions in the manual p. 444.
If 607 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Fagor service.