Fagor Servo Drive System Error 157: Actual position deviation exceeded.

Fagor Servo Drive System · taken from the manufacturer’s manual, pages cited

Error code157

Actual position deviation exceeded means the difference between the first‑order and second‑order feedback device position values exceeds the maximum value specified by parameter PP5 by at least 20 ms. The manual's first action is: “Check the value of PP5 (the range may be too small).”

Model
Fagor Servo Drive System
Display shows
Actual position deviation exceeded. (157)
Type
Error code
Source
Manual p. 546

What 157 means

Actual position deviation exceeded. p. 546

Common causes

  • The difference between the first‑order and second‑order feedback device position values exceeds the maximum value specified by parameter PP5 (S391) ActualPositionMonitoringWindow by at least 20 ms. p. 546
  • Check that the difference between PV190 and PP5 does not exceed a certain proportion; if it does, the feedback parameters are set incorrectly, or there may be problems with the connection cables, feedback devices, etc. p. 546

What to do

  1. Check the value of PP5 (the range may be too small). p. 546

Before you service the product, read the safety instructions in the manual p. 444.

If 157 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Fagor service.

This page summarises what the manufacturer’s manual says about 157; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fagor. Found a mistake? Report an error.