Actual position deviation exceeded means the difference between the first‑order and second‑order feedback device position values exceeds the maximum value specified by parameter PP5 by at least 20 ms. The manual's first action is: “Check the value of PP5 (the range may be too small).”
- Model
- Fagor Servo Drive System
- Display shows
- Actual position deviation exceeded. (157)
- Type
- Error code
- Source
- Manual p. 546
What 157 means
Actual position deviation exceeded. p. 546
Common causes
- The difference between the first‑order and second‑order feedback device position values exceeds the maximum value specified by parameter PP5 (S391) ActualPositionMonitoringWindow by at least 20 ms. p. 546
- Check that the difference between PV190 and PP5 does not exceed a certain proportion; if it does, the feedback parameters are set incorrectly, or there may be problems with the connection cables, feedback devices, etc. p. 546
What to do
- Check the value of PP5 (the range may be too small). p. 546
Before you service the product, read the safety instructions in the manual p. 444.
If 157 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Fagor service.