Fagor Servo Drive System Error 150: Travel limit exceeded.

Fagor Servo Drive System · taken from the manufacturer’s manual, pages cited

Error code150

Travel limit exceeded means the travel limits set by PP49 and PP50 have been exceeded. The manual's first action is: “The error opens the DR_OK (drive OK) contact in the drive. Once power to the servo system is restored, the axis must be moved into the working area (within travel limits). Check these limit values and the programmed motion to prevent recurrence.”

Model
Fagor Servo Drive System
Display shows
Travel limit exceeded. (150)
Type
Error code
Source
Manual p. 545

What 150 means

Travel limit exceeded. p. 545

Common causes

  • Exceeded the travel limits set by PP49 and PP50. p. 545

What to do

  1. The error opens the DR_OK (drive OK) contact in the drive. Once power to the servo system is restored, the axis must be moved into the working area (within travel limits). Check these limit values and the programmed motion to prevent recurrence. p. 545

Before you service the product, read the safety instructions in the manual p. 444.

If 150 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Fagor service.

This page summarises what the manufacturer’s manual says about 150; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fagor. Found a mistake? Report an error.