Travel limit exceeded means the travel limits set by PP49 and PP50 have been exceeded. The manual's first action is: “The error opens the DR_OK (drive OK) contact in the drive. Once power to the servo system is restored, the axis must be moved into the working area (within travel limits). Check these limit values and the programmed motion to prevent recurrence.”
- Model
- Fagor Servo Drive System
- Display shows
- Travel limit exceeded. (150)
- Type
- Error code
- Source
- Manual p. 545
What 150 means
Travel limit exceeded. p. 545
Common causes
- Exceeded the travel limits set by PP49 and PP50. p. 545
What to do
- The error opens the DR_OK (drive OK) contact in the drive. Once power to the servo system is restored, the axis must be moved into the working area (within travel limits). Check these limit values and the programmed motion to prevent recurrence. p. 545
Before you service the product, read the safety instructions in the manual p. 444.
If 150 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Fagor service.
This page summarises what the manufacturer’s manual says about 150; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Fagor. Found a mistake? Report an error.