Fault code14
The motor cable connection is abnormal or there is an imbalance among the three phases of the motor. The manual's first action is: “Check motor connection”
- Model
- Emotron VSU
- Display shows
- oPL (14)
- Type
- Fault code
- Source
- Manual p. 253
What 14 means
oPL p. 253
Common causes
- Motor cable connection abnormal p. 253
- Imbalance among motor three phases p. 253
- Incorrect setting of vector control parameters p. 253
What to do
- Check motor connection p. 253
- Check or replace the motor p. 253
- Correctly set vector control parameters p. 253
Before you service the product, read the safety instructions in the manual p. 7.
If 14 is still not resolved
- Contact service or dealer for assistance. p. 253 “Check motor connection, Check or replace the motor, Correctly set vector control parameters”
This page summarises what the manufacturer’s manual says about 14; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Emotron. Found a mistake? Report an error.