Fault code15
Code 15 indicates the thermistor input of option board indicates overtemperature with fault or warning depending on ID732, or the motor torque is beyond the set supervision low limit/high limit (ID348 and ID349). The manual lists no action for this code.
- Model
- Eaton SPX9000 AF
- Display shows
- Thermistor fault or warning (Application 2) (15)
- Type
- Fault code
- Source
- Manual p. 149
What 15 means
Thermistor fault or warning (Application 2) p. 149
Common causes
- The thermistor input of option board indicates overtemperature. Fault or warning depending on ID732. p. 149
- The motor torque is beyond the set supervision low limit/ high limit (ID348 and ID349). p. 149
If 15 is still not resolved
- Disconnect power before checking controllers or performing maintenance. p. 10 “Disconnect power before checking controllers or performing maintenance.”
This page summarises what the manufacturer’s manual says about 15; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Eaton. Found a mistake? Report an error.