Fault codeCF

Code CF means the system stops at CF due to insufficient DRAM voltage, incompatible memory modules, or an overclocking issue (tight DRAM timing). The manual's first action is: “1. Increase the DRAM’s voltage.”

Model
DFI X48‑T3RS
Display shows
Stopped at CF (CF)
Type
Fault code
Source
Manual p. 125

What CF means

Stopped at CF p. 125

Common causes

  • 1. Insufficient DRAM voltage. p. 125
  • 2. Incompatible memory modules. p. 125
  • 3. Overclocking issue (tight DRAM timing). p. 125
  • 4. BIOS issue. p. 125

What to do

  1. 1. Increase the DRAM’s voltage. p. 125
  2. 2. Remove and reinstall the memory modules. p. 125
  3. 3. Load the default DRAM speed. p. 125
  4. 4. Upgrade to the latest BIOS. p. 125

If CF is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact DFI service.