Fault codeC1

Code C1 means the system stops at C1 due to incompatible memory modules, an overclocking issue (tight DRAM timing), or one of the memory modules being defective. The manual's first action is: “1. Remove and reinstall the memory modules.”

Model
DFI X48‑T3RS
Display shows
Stopped at C1 (C1)
Type
Fault code
Source
Manual p. 125

What C1 means

Stopped at C1 p. 125

Common causes

  • 1. Incompatible memory modules. p. 125
  • 2. Overclocking issue (tight DRAM timing). p. 125
  • 3. One of the memory modules is defective. p. 125

What to do

  1. 1. Remove and reinstall the memory modules. p. 125
  2. 2. Clear the CMOS then load the default speed. p. 125
  3. 3. Try installing a single module only. p. 125

If C1 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact DFI service.