DFI 790FX B Series Error C1

DFI 790FX B Series system board · taken from the manufacturer’s manual, pages cited

Fault codeC1

Code C1 means incompatible memory modules, an overclocking issue with tight DRAM timing, or a defective memory module. The manual's first action is: “1. Remove and reinstall the memory modules.”

Model
DFI 790FX B Series
Display shows
C1
Type
Fault code
Source
Manual p. 141

What C1 means

1. Incompatible memory modules. p. 141

Common causes

  • 1. Incompatible memory modules. p. 141
  • 2. Overclocking issue (tight DRAM timing). p. 141
  • 3. One of the memory modules is defective. p. 141

What to do

  1. 1. Remove and reinstall the memory modules. p. 141
  2. 2. Clear the CMOS then load the default speed. p. 141
  3. 3. Try installing a single module only. p. 141

If C1 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact DFI service.