oSL occurs when slip exceeds the setting of parameter 07-29 and duration exceeds parameter 07-30. The manual's first action is: “Confirm the set values of parameters 07‑29 and 07‑30; set parameter 07‑31 to 0, 1, or 2.”
- Model
- Delta CP2000
- Display shows
- oSL
- Type
- Error code
- Source
- Manual p. 337
What oSL means
oSL occurs when slip exceeds the setting of parameter 07‑29 and the duration exceeds the setting of parameter 07‑30 p. 337
Common causes
- Check whether the motor parameters are correct; if the load is too high, reduce the load. p. 337
What to do
- Confirm the set values of parameters 07‑29 and 07‑30; set parameter 07‑31 to 0, 1, or 2. p. 337
Before you service the product, read the safety instructions in the manual p. 327.
If oSL is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.
This page summarises what the manufacturer’s manual says about oSL; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.