Delta CP2000 Error oH3: Motor over heat

Variable frequency drive · taken from the manufacturer’s manual, pages cited

Error codeoH3

The AC motor drive detects that the motor internal temperature is too high, exceeding the protection setpoint (parameter 06‑30 PTC). The manual's first action is: “Check whether the motor is stalled; check if ambient temperature is too high; increase motor capacity.”

Model
Delta CP2000
Display shows
Motor over heat (oH3)
Type
Error code
Source
Manual p. 334

What oH3 means

Motor over heat p. 334

Common causes

  • The AC motor drive detects that the motor internal temperature is too high, exceeding the protection setpoint (parameter 06‑30 PTC). p. 334

What to do

  1. Check whether the motor is stalled; check if ambient temperature is too high; increase motor capacity. p. 334

Before you service the product, read the safety instructions in the manual p. 327.

If oH3 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Delta service.

This page summarises what the manufacturer’s manual says about oH3; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Delta. Found a mistake? Report an error.