ING 40 means a fault was encountered during automatic motor adjustment. The manual's first action is: “Check possible causes according to the warning message. If you wish for AMA to ignore the warning and continue operation, press the [CHANGE DATA] (Change Data) key and select [CONTINUE] (Continue); if you wish to interrupt AMA, press the [STOP/RESET] (Stop/Reset) key or disconnect terminal 18 from terminal 12.”
- Model
- Danfoss 5000
- Display shows
- Fault encountered during automatic motor adjustment. (ING 40)
- Type
- Warning code
- Source
- Manual p. 87
What ING 40 means
Fault encountered during automatic motor adjustment. p. 87
Common causes
- Fault encountered during automatic motor adjustment. p. 87
What to do
- Check possible causes according to the warning message. If you wish for AMA to ignore the warning and continue operation, press the [CHANGE DATA] (Change Data) key and select [CONTINUE] (Continue); if you wish to interrupt AMA, press the [STOP/RESET] (Stop/Reset) key or disconnect terminal 18 from terminal 12. p. 87
Before you service the product, read the safety instructions in the manual p. 133.
If ING 40 is still not resolved
- Contact the Danfoss supplier. p. 161 “请与 Danfoss 供应 商联系。”
This page summarises what the manufacturer’s manual says about ING 40; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Danfoss. Found a mistake? Report an error.