Danaher Motion S200 Error 9: Motor H or I-n Short

Danaher Motion S200 · taken from the manufacturer’s manual, pages cited

Fault code9

Motor H or I-n Short indicates motor power wiring short circuit line-to-ground or neutral, motor cable short line-to-line, or internal motor winding short circuit. The manual lists no action for this code.

Model
Danaher Motion S200
Display shows
Motor H or I-n Short (9)
Type
Fault code
Source
Manual p. 98

What 9 means

Motor H or I-n Short p. 98

Common causes

  • Motor power wiring short circuit - line-to-ground / neutral. p. 98
  • Motor cable short line-to-line. p. 98
  • Internal motor winding short circuit. p. 98
  • KIP set too large. p. 98

If 9 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Danaher Motion service.

This page summarises what the manufacturer’s manual says about 9; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Danaher Motion. Found a mistake? Report an error.