Danaher Motion S200 Error 4: Drive I*t Too High

Danaher Motion S200 · taken from the manufacturer’s manual, pages cited

Fault code4

Drive I*t Too High indicates a mechanically-jammed motor, motion profile acceleration requiring peak current for too long of a time duration, machine load on the motor increased by friction, or wiring problem between drive and motor. The manual lists no action for this code.

Model
Danaher Motion S200
Display shows
Drive I*t Too High (4)
Type
Fault code
Source
Manual p. 98

What 4 means

Drive I*t Too High p. 98

Common causes

  • Mechanically-jammed motor. Motion profile acceleration requires peak current for too long of a time duration. Machine load on the motor increased by friction. Wiring problem between drive and motor yielding improper motion. Motor commutation error. Drive under-sized for application, friction or load. p. 98

If 4 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Danaher Motion service.

This page summarises what the manufacturer’s manual says about 4; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Danaher Motion. Found a mistake? Report an error.