Error code**1022
Password protection error due to incorrect password input, upload protection set on PLC, or digit change during new password setup. The manual's first action is: “Input the correct password after turning the power supply off and then on again.”
- Model
- CLRWTR GT Series
- Display shows
- Password protection error (**1022)
- Type
- Error code
- Source
- Manual p. 119
What **1022 means
Password protection error p. 119
Common causes
- (1) Incorrect passwords were input three times or more. p. 119
- (2) The upload protection has been set for the PLC. p. 119
- (3) The number of digits was changed when setting a new password. p. 119
What to do
- Input the correct password after turning the power supply off and then on again. p. 119
- Cancel the password with the FP monitor function. p. 119
- Cancel the password first to change the number of digits. p. 119
Before you service the product, read the safety instructions in the manual p. 2.
If **1022 is still not resolved
- contact service / dealer p. 2 “Do NOT USE THE PROGRAMMABLE DISPLAY TO CONTROL SAFETY FEATURES OR OTHER CRITICAL OPERATIONS OF EQUIPMENT OR SYSTEMS.”
- contact service / dealer p. 2 “A COMMUNICATION ERROR (FOR ANY REASON) MIGHT PREVENT SUCH SAFETY FEATURES OR CRITICAL OPERATIONS FROM FUNCTIONING PROPERLY.”
This page summarises what the manufacturer’s manual says about **1022; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with CLRWTR. Found a mistake? Report an error.