Brother HE-800A Error E-96: Power supply voltage abnormal (low)

Brother HE-800A sewing machine · taken from the manufacturer’s manual, pages cited

Error codeE-96

Power supply voltage abnormal (low) means the power supply voltage is too low. The manual's first action is: “1. Turn off the power.”

Model
Brother HE-800A
Display shows
Power supply voltage abnormal (low) (E-96)
Type
Error code
Source
Manual p. 96

What E-96 means

Power supply voltage abnormal (low) p. 96

What to do

  1. 1. Turn off the power. p. 96
  2. 2. Verify the voltage being used and the voltage specified by the control box specifications. p. 96
  3. 3. Verify the connection positions of CN2, CN3, and CN4 on the first-layer power board. p. 96
  4. • For 200 V models … CN2 p. 96
  5. • For 100 V, 110 V, 240 V, 220 V, 380 V, 400 V, 415 V models … CN3 p. 96
  6. • For 230 V models … CN4 p. 96

Before you service the product, read the safety instructions in the manual p. 80.

If E-96 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Brother service.

This page summarises what the manufacturer’s manual says about E-96; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Brother. Found a mistake? Report an error.