This is the list of fault, error codes the Brother manual gives for the HE-800A Brother HE-800A sewing machine. Find your code below and open it for what the manual says about its causes and what to do.
Fault codes from p. 93
| Code | Display message | What it means | Page |
|---|---|---|---|
E-00 |
Pause switch pressed | 按了暂停开关 | p. 93 |
E-01 |
Upper thread broken | 面线已断 | p. 93 |
E-02 |
Needle start sensor is OFF | 起针感应器处于OFF状态 | p. 93 |
E-30 |
Foot pedal stuck in 2nd gear position | 踏板被踩到了第 2 档位置 | p. 94 |
E-53 |
Knife multiple‑cut fault | 切刀多重切割故障 | p. 94 |
E-62 |
Needle‑start error during operation | 动作中起针出错 | p. 95 |
E-63 |
Needle‑drop error during operation | 动作中落针出错 | p. 95 |
E-64 |
Time signal error during operation | 动作中时间信号出错 | p. 95 |
Error codes from p. 93
| Code | Display message | What it means | Page |
|---|---|---|---|
E-05 |
Needle bar position uncertain | 针摆位置不确定 | p. 93 |
E-06 |
Fabric feed position uncertain | 送布位置不确定 | p. 93 |
E-07 |
Presser foot position uncertain | 压脚位置不确定 | p. 93 |
E-08 |
Knife home sensor is OFF | 切刀原点感应器处于OFF状态 | p. 93 |
E-20 |
Fabric feed or presser‑foot motor overcurrent | 送布、压脚马达过电流 | p. 94 |
E-21 |
Needle‑bar motor overcurrent | 针摆马达过电流 | p. 94 |
E-31 |
Foot pedal stuck in 1st gear position | 踏板被踩到了第 1 档位置 | p. 94 |
E-32 |
Foot pedal pressed in reverse | 在倒踩踏板 | p. 94 |
E-40 |
Control board heatsink overheating | 控制基板的散热器过热 | p. 94 |
E-41 |
Air‑circulation fan inside the cabinet abnormal | 箱内空气循环用风扇异常 | p. 94 |
E-42 |
Exhaust fan abnormal | 排气风扇异常 | p. 94 |
E-44 |
Second‑layer power board +55 V relay abnormal | 2 层电源基板 +55V 继电器异常 | p. 94 |
E-51 |
X spacing error | X 间距出错 | p. 94 |
E-52 |
Y spacing error | Y 间距出错 | p. 94 |
E-54 |
Loop program total stitch count error (exceeds 3000 stitches) | 循环程序总针数错误(超过了 3000 针) | p. 94 |
E-55 |
Stitch count error (exceeds 700 stitches) | 针数出错(超过了700针) | p. 95 |
E-59 |
Sewing data error | 缝制数据出错 | p. 95 |
E-70 |
Sewing machine motor reverse error | 缝纫机马达反转出错 | p. 95 |
E-74 |
EEPROM error | EEPROM 出错 | p. 95 |
E-80 |
Communication preparation error | 通信准备出错 | p. 95 |
E-81 |
Communication error | 通信出错 | p. 95 |
E-90 |
Sewing machine motor overload (excessive load during sewing) | 缝纫机马达过负荷(缝制时的负荷大) | p. 95 |
E-92 |
Sewing machine motor abnormal rotation | 缝纫机马达旋转异常 | p. 96 |
E-93 |
Electromagnet fuse blown | 电磁铁的保险丝烧断 | p. 96 |
E-94 |
Sewing machine motor IC abnormal | 缝纫机马达的 IC 异常 | p. 96 |
E-95 |
Power supply voltage abnormal (high) | 电源电压异常(高) | p. 96 |
E-96 |
Power supply voltage abnormal (low) | 电源电压异常(低) | p. 96 |
E-97 |
Sewing machine motor locked • Excessive load during sewing • Motor temperature protection activated (applicable to motors with manufacturing number “G03xxxxxx” and later) | 缝纫机马达锁定 · 缝制时的负荷过大 · 马达的温度保护功能起作用(马达制造编号“G03xxxxxx”以后的产品) | p. 96 |
ArEA |
Sewing data exceeds the needle plate size or presser foot size set by the operation panel switch group | 缝制数据超过了用操作盘开关组所设置的针板尺寸、压脚尺寸 | p. 96 |
Codes and descriptions are taken from the manufacturer’s manual; page numbers link to the PDF. ManualLib is not affiliated with Brother. Found a mistake? Report an error.