Beijing-Fanuc 0i-MA Error 49: In interpolation speed mode, the speed of another spindle converted to the local spindle speed exceeds the allowed value. (The interpolated speed is obtained by multiplying the other spindle's speed by the speed ratio.)

Beijing-Fanuc 0i-MA · taken from the manufacturer’s manual, pages cited

Error code49

In interpolation speed mode, the speed of another spindle converted to the local spindle speed exceeds the allowed value. The manual's first action is: “Check whether the calculated interpolated speed exceeds the maximum motor speed.”

Model
Beijing-Fanuc 0i-MA
Display shows
49
Type
Error code
Source
Manual p. 741

What 49 means

In interpolation speed mode, the speed of another spindle converted to the local spindle speed exceeds the allowed value. (The interpolated speed is obtained by multiplying the other spindle's speed by the speed ratio.) p. 741

Common causes

  • In interpolation speed mode, the speed of another spindle converted to the local spindle speed exceeds the allowed value. (The interpolated speed is obtained by multiplying the other spindle's speed by the speed ratio.) p. 741

What to do

  1. Check whether the calculated interpolated speed exceeds the maximum motor speed. p. 741

Before you service the product, read the safety instructions in the manual p. 18.

If 49 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.

This page summarises what the manufacturer’s manual says about 49; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.