Beijing-Fanuc 0i-MA Error 47

Beijing-Fanuc 0i-MA · taken from the manufacturer’s manual, pages cited

Error code47

The spindle position encoder connected to JY4 or the A/B phase signals of MZ or BZ connected to JY2 have abnormal signals. The manual's first action is: “1. Replace the cable. 2. Re‑adjust the BZ sensor signal. 3. Modify the cable wiring (near the power lines).”

Model
Beijing-Fanuc 0i-MA
Display shows
47
Type
Error code
Source
Manual p. 741

What 47 means

1. The spindle position encoder (connected to JY4) has abnormal A/B phase signals. 2. The A/B phase signals of MZ or BZ (connected to JY2) are abnormal. The relationship between the A/B phases and the 1‑turn signal is incorrect (pulse time interval is improperly matched). p. 741

Common causes

  • 1. The spindle position encoder (connected to JY4) has abnormal A/B phase signals. 2. The A/B phase signals of MZ or BZ (connected to JY2) are abnormal. The relationship between the A/B phases and the 1‑turn signal is incorrect (pulse time interval is improperly matched). p. 741

What to do

  1. 1. Replace the cable. 2. Re‑adjust the BZ sensor signal. 3. Modify the cable wiring (near the power lines). p. 741

Before you service the product, read the safety instructions in the manual p. 18.

If 47 is still not resolved

The manual gives no further instruction for this code. Open the code table in the PDF or contact Beijing-Fanuc service.

This page summarises what the manufacturer’s manual says about 47; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Beijing-Fanuc. Found a mistake? Report an error.