The system lost its flame signal after a fan purge attempt. The manual's first action is: “Check flame sensing electrode and lead Check for flue gas recirculation Check/adjust the gas valve settings Check/adjust the fan speed settings”
- Model
- Alpha InTec 30C, 34C
- Display shows
- Loss of flame rectification (38)
- Type
- Fault code
- Source
- Manual p. 42
What 38 means
Loss of flame rectification p. 42
Common causes
- Flame detected but signal is lost. Ignition reattempts after fan purge p. 42
What to do
- Check flame sensing electrode and lead Check for flue gas recirculation Check/adjust the gas valve settings Check/adjust the fan speed settings p. 42
If 38 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Alpha InTec service.
This page summarises what the manufacturer’s manual says about 38; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Alpha InTec. Found a mistake? Report an error.