02 on the Alpha InTec 30C, 34C is listed in the manual as: Overheat boiler lock out. The manual lists no action for this code.
- Model
- Alpha InTec 30C, 34C
- Display shows
- Overheat boiler lock out (02)
- Type
- Fault code
- Source
- Manual p. 41
What 02 means
Overheat boiler lock out p. 41
Common causes
- Pump or flow problem p. 41
- Blocked heat exchanger p. 41
- Air in heat exchanger p. 41
- Overheat thermostat p. 41
- Thermal fuse (if open circuit then replace primary heat exchanger) p. 41
If 02 is still not resolved
The manual gives no further instruction for this code. Open the code table in the PDF or contact Alpha InTec service.
This page summarises what the manufacturer’s manual says about 02; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with Alpha InTec. Found a mistake? Report an error.