Motor speed is greater than 120% of the larger (in magnitude) of 2001 MINIMUM SPEED or 2002 MAXIMUM SPEED. The manual's first action is: “Check for and correct: • Parameter settings for 2001 and 2002. • Adequacy of motor braking torque. • Applicability of torque control. • Brake chopper and resistor.”
- Model
- ABB ACS550-01 / ACS550-U1
- Display shows
- OVERSPEED (24)
- Type
- Fault code
- Source
- Manual p. 245
What 24 means
OVERSPEED p. 263
Common causes
- Motor speed is greater than 120% of the larger (in magnitude) of 2001 MINIMUM SPEED or 2002 MAXIMUM SPEED. p. 263
What to do
- Check for and correct: • Parameter settings for 2001 and 2002. • Adequacy of motor braking torque. • Applicability of torque control. • Brake chopper and resistor. p. 263
Before you service the product, read the safety instructions in the manual p. 6.
If 24 is still not resolved
- contact your local ABB representative for replacement p. 6 “Never attempt to repair a malfunctioning drive; contact your local ABB representative for replacement.”
- For more technical information, contact your local ABB representative. p. 7 “For more technical information, contact your local ABB representative.”