Error code1013
PAR PFC IO 2 indicates mismatch between number of PFC motors and configured relay outputs. The manual lists no action for this code.
- Model
- ABB ACS550-01 / ACS550-U1
- Display shows
- PAR PFC IO 2 (1013)
- Type
- Error code
- Source
- Manual p. 246
What 1013 means
PAR PFC IO 2 p. 246
Common causes
- IO configuration is not complete – the actual number of PFC motors (parameter 8127, MOTORS) does not match the PFC motors in Group 14: RELAY OUTPUTS and parameter 8118 AUTOCHNG INTERV. p. 246
If 1013 is still not resolved
- contact your local ABB representative for replacement p. 6 “Never attempt to repair a malfunctioning drive; contact your local ABB representative for replacement.”
- For more technical information, contact your local ABB representative. p. 7 “For more technical information, contact your local ABB representative.”