DC OVERVOLTAGE indicates a DC overvoltage due to power supply, deceleration time, or brake chopper size. The manual's first action is: “1. Check whether the power supply is overvoltage long‑term or momentarily 2. Deceleration time may be too short (parameters 2203 DECELER TIME 1 and 2205 DECELER TIME 2) 3. Brake chopper size does not match the inverter.”

Model
ABB ACS400
Display shows
DC OVERVOLTAGE (2)
Type
Error code
Source
Manual p. 152

What 2 means

DC OVERVOLTAGE p. 152

Common causes

What to do

  1. 1. Check whether the power supply is overvoltage long‑term or momentarily 2. Deceleration time may be too short (parameters 2203 DECELER TIME 1 and 2205 DECELER TIME 2) 3. Brake chopper size does not match the inverter. p. 152