ABB ACS400 Error 1: OVERCURRENT

ABB ACS400 frequency converter · taken from the manufacturer’s manual, pages cited

Fault code1

OVERCURRENT indicates an overcurrent due to load, acceleration time, or motor/motor cable fault. The manual's first action is: “1. Load too large 2. Acceleration time too short (parameters 2202 ACCELER TIME 1 and 2204 ACCELER TIME 2) 3. Motor or motor cable fault or incorrect connection.”

Model
ABB ACS400
Display shows
OVERCURRENT (1)
Type
Fault code
Source
Manual p. 152

What 1 means

OVERCURRENT p. 152

Common causes

What to do

  1. 1. Load too large 2. Acceleration time too short (parameters 2202 ACCELER TIME 1 and 2204 ACCELER TIME 2) 3. Motor or motor cable fault or incorrect connection. p. 152

Before you service the product, read the safety instructions in the manual p. 91.

If 1 is still not resolved

  • contact the supplier p. 3
    “不要试图修理损坏的单元,请与供应商联系”
  • contact the supplier p. 3
    “欲获取详细的技术信息,请与供应商联系”

This page summarises what the manufacturer’s manual says about 1; each statement links to the page it comes from, and quoted lines are copied word for word. It is not a substitute for the manual or for a qualified installer. ManualLib is not affiliated with ABB. Found a mistake? Report an error.