The drive is warning that its heatsink is overheating and a device overtemperature fault may occur soon. The manual's first action is: “Check for and correct: Fan failure. Obstructions in the air flow. Dirt or dust coating on the heat sink. Excessive ambient temperature. Excessive motor load.”
- Model
- ABB ACH550
- Display shows
- DEVICE OVERTEMP (2009)
- Type
- Alarm code
- Source
- Manual p. 30
What 2009 means
DEVICE OVERTEMP p. 30
Common causes
- Drive heatsink is hot. This alarm warns that a DEVICE OVERTEMP fault may be near. p. 30
What to do
- Check for and correct: Fan failure. Obstructions in the air flow. Dirt or dust coating on the heat sink. Excessive ambient temperature. Excessive motor load. p. 30
Before you service the product, read the safety instructions in the manual p. 2.
If 2009 is still not resolved
- contact the factory or your local Authorized Service Center for repair or replacement. p. 2 “Never attempt to repair a malfunctioning ACH550; contact the factory or your local Authorized Service Center for repair or replacement.”