ABB ACH550 Error 1: OVERCURRENT

AC drive · taken from the manufacturer’s manual, pages cited

Fault code1

OVERCURRENT means output current is excessive due to motor load, acceleration time settings, or faulty components. The manual's first action is: “Check for and correct: Excessive motor load. Insufficient acceleration time (parameters 2202 ACCELER TIME 1 and 2205 ACCELER TIME 2). Faulty motor, motor cables or connections. Output disconnect device not interlocked. Interaction with external input filter.”

Model
ABB ACH550
Display shows
OVERCURRENT (1)
Type
Fault code
Source
Manual p. 24

What 1 means

OVERCURRENT p. 24

Common causes

  • Output current is excessive. p. 24

What to do

  1. Check for and correct: Excessive motor load. Insufficient acceleration time (parameters 2202 ACCELER TIME 1 and 2205 ACCELER TIME 2). Faulty motor, motor cables or connections. Output disconnect device not interlocked. Interaction with external input filter. p. 24

Before you service the product, read the safety instructions in the manual p. 2.

If 1 is still not resolved

  • contact the factory or your local Authorized Service Center for repair or replacement. p. 2
    “Never attempt to repair a malfunctioning ACH550; contact the factory or your local Authorized Service Center for repair or replacement.”