Programming Manual

Instruction set, parameters and examples for configuring or programming the device.

User Manual

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in Collihigh manuals

How do I read the version information of the transmitter?

Send the command "#<address>99<checksum><CR>"; the device returns the version string such as "KL‑NETY ALI‑V4.0".

From: Network Pressure Transmitter V1.10 Protocol Manual

Which characters can be used as command delimiters?

The valid delimiters are #, $, %, &, *, ! and ?.

From: Network Pressure Transmitter V1.10 Protocol Manual

What CRC algorithm does the protocol use?

It uses a CRC‑16 algorithm with polynomial 0xA001, and sample C code is provided in the document.

From: Kunlun ColliHigh Network Temperature and Humidity Transmitter Communication Protocol

What power source does the JWSK‑SC use?

It is powered by four 1.5 V batteries (total 6 V).

From: Kunlun Coast JWSK-SC Handheld Temperature and Humidity Meter User Manual

What are the measurement ranges for temperature and humidity?

Temperature can be measured from –20 °C to 60 °C, and humidity from 0 % RH to 100 % RH (non‑condensing).

From: Kunlun Coast JWSK-SC Handheld Temperature and Humidity Meter User Manual

How can I change the transmitter's communication address?

Send a Modbus write command (function 0x06) with the new address, e.g., 0x06 00 03 new_address, then power‑cycle the unit to apply the change.