Key facts
- Manuals
- 23
- Models
- 3
- Categories
- 1
- Languages
- ZH · JA
- Last added
- 2012-04-12
Collihigh models by category
Featured Collihigh manuals

Network Pressure Transmitter V1.10 Protocol Manual
The document explains how to install the test software, select the hexadecimal send mode, and manually transmit commands to the transmitter. It shows the user interface of the serial debugging tool and the steps to send and clear commands.
It then details the communication elements such as baud‑rate options, data format, transmission standards, address range, delimiters, checksum calculation and the full list of commands for reading, writing and controlling the device, including error response handling. This manual is written in Chinese.
Covers: Communication Elements · Data Frame Format · Command Set List · Command Details · Error Responses · Output Control Commands

Kunlun ColliHigh Network Temperature and Humidity Transmitter Communication Protocol
The protocol follows the MODBUS standard using a 16‑bit hexadecimal format. A master device sends a request and the transmitter replies with temperature and humidity data, each split into high and low bytes. The CRC high and low bytes are appended for error checking.
Configuration of the device is performed via two groups of dip switches: one group selects the baud rate (1200, 2400, 4800, 9600 bit/s) and the other sets the device address (default 01). The document also provides a C‑language implementation of the CRC‑16 algorithm (polynomial 0xA001) for developers. This manual is written in Chinese.
Covers: MODBUS Protocol Overview · Data Format · Frame Format · Baud Rate Settings · Address Settings · CRC Check Algorithm

Kunlun Coast JWSK-SC Handheld Temperature and Humidity Meter User Manual
The JWSK-SC handheld temperature and humidity meter provides precise measurements using an imported sensor and temperature compensation circuitry. It features a 128 × 64 LCD, zero‑point correction, adjustable sleep time, and dew‑point measurement.
The manual explains installation, menu navigation, parameter adjustments, and safety precautions, ensuring reliable operation in indoor, telecom, building automation, and other environments. This manual is written in Chinese.
Covers: Introduction · Applications · Technical Specifications · Physical Dimensions and Installation · Menu Description · Precautions

Kunlun Coast JWSK-5 Temperature Humidity Transmitter User Manual
The JWSK-5 series is an industrial‑grade temperature and humidity transmitter capable of measuring –40 °C to 120 °C and 0 %RH to 100 %RH. It offers multiple analog outputs (0–5 V, 0–10 V, 4–20 mA) and optional RS485 or RS232 network interfaces, with a 128 × 64 LCD display showing temperature, humidity and dew‑point.
The manual covers product overview, technical parameters, physical dimensions and wiring diagrams, step‑by‑step installation for wall‑mount, pipe‑mount and split‑type units, operation of the LCD menu, communication settings (Modbus RTU), maintenance, storage, unpacking inspection, and detailed fault analysis with troubleshooting procedures. This manual is written in Chinese.
Covers: Overview · Technical Specifications · Physical Dimensions and Wiring · Installation · Operation · Precautions
Latest Collihigh manuals
ColliHigh NWSF-1AT temperature transmitter Manual
The JQBW-8 series dust transmitter is an intelligent instrument with liquid crystal display, three-wire 4mA~20mA output and menu setting function. Its biggest feature is low power consumption and friendly human-machine interface, easy to operate. This product is mainly used in electronic, pharmaceutical, air purification, food hygiene, hospitals, air purification and other fields.
Network Pressure Transmitter V1.10 Protocol Manual
Programming Manual 6 pages · 272 KB · ZHThis manual describes the communication protocol, command set and data frame format for the Network Pressure Transmitter V1.10.
Kunlun ColliHigh Network Temperature and Humidity Transmitter Communication Protocol
Programming Manual 3 pages · 114 KB · ZHThis document details the MODBUS‑compatible communication protocol for the Kunlun ColliHigh network temperature and humidity transmitter.
Kunlun Coast JWSK-SC Handheld Temperature and Humidity Meter User Manual
User Manual 3 pages · 249 KB · ZHUser manual for the Kunlun Coast JWSK-SC handheld temperature and humidity meter, covering setup, operation, menus, and safety.
Kunlun Coast JWSK-5 Temperature Humidity Transmitter User Manual
User Manual 7 pages · 377 KB · ZHThe JWSK-5 temperature and humidity transmitter manual provides overview, specifications, installation, wiring, operation, and troubleshooting instructions.
Kunlun Coast Sensor JWSK-6 Wide-Temperature Network Temperature & Humidity Transmitter User Manual
User Manual 4 pages · 309 KB · ZHUser manual for the JWSK-6 wide‑temperature network temperature and humidity transmitter, covering specifications, installation, operation and troubleshooting.
Collihigh JWSK-8 Series Temperature Humidity Transmitter User Manual
User Manual 8 pages · 400 KB · ZHUser manual for the Collihigh JWSK-8 temperature‑humidity transmitter covering installation, operation, maintenance and troubleshooting.
Kunlun Coast Sensor JYB-KO-PAHG Pressure Transmitter User Manual
User Manual 1 pages · 177 KB · ZHThe JYB-KO-PAHG pressure transmitter manual provides features, specifications, installation, wiring, safety, and troubleshooting instructions.
Kunlun Coast JYB-A Temperature & Pressure Transmitter User Manual
User Manual 1 pages · 176 KB · ZHThe Kunlun Coast JYB-A temperature and pressure transmitter manual provides specifications, installation, wiring, operation, and troubleshooting guidance.
Collihigh R Ver 3.5 Temperature Transmitter User Manual
User Manual 12 pages · 230 KB · ZHThe Collihigh R Ver 3.5 temperature transmitter manual provides overview, model naming, technical specs, wiring diagrams and safety precautions.
ColliHigh JWSK-5 Temperature & Humidity Controller User Manual
User Manual 4 pages · 279 KB · ZHThe ColliHigh JWSK-5 temperature and humidity controller manual provides installation, wiring, operation, and maintenance instructions.
Collihigh JZH-0 Series Wireless Sensor User Manual
User Manual 4 pages · 638 KB · ZHThe Collihigh JZH-0 Series Wireless Sensor User Manual provides overview, technical specifications, installation steps, parameter settings, and operation…
Kunlun Coast JYB-G ZigBee Wireless Pressure Transmitter User Manual
User Manual 3 pages · 355 KB · ZHThe manual explains features, specifications, installation, operation, wireless communication and troubleshooting for the JYB‑G ZigBee wireless pressure…
Collihigh KL-M6000 Ethernet Module User Manual
User Manual 1 pages · 207 KB · ZHThe Collihigh KL-M6000 Ethernet module manual provides installation, configuration, and operation instructions for the 8‑channel analog data acquisition device.
ColliHigh jyb-g Wireless pressure Meter Manual
- 1
- 2
Which document do I need?
Programming Manual
Instruction set, parameters and examples for configuring or programming the device.
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Collihigh manuals
How do I read the version information of the transmitter?
Send the command "#<address>99<checksum><CR>"; the device returns the version string such as "KL‑NETY ALI‑V4.0".
Which characters can be used as command delimiters?
The valid delimiters are #, $, %, &, *, ! and ?.
What CRC algorithm does the protocol use?
It uses a CRC‑16 algorithm with polynomial 0xA001, and sample C code is provided in the document.
From: Kunlun ColliHigh Network Temperature and Humidity Transmitter Communication Protocol
What power source does the JWSK‑SC use?
It is powered by four 1.5 V batteries (total 6 V).
From: Kunlun Coast JWSK-SC Handheld Temperature and Humidity Meter User Manual
What are the measurement ranges for temperature and humidity?
Temperature can be measured from –20 °C to 60 °C, and humidity from 0 % RH to 100 % RH (non‑condensing).
From: Kunlun Coast JWSK-SC Handheld Temperature and Humidity Meter User Manual
How can I change the transmitter's communication address?
Send a Modbus write command (function 0x06) with the new address, e.g., 0x06 00 03 new_address, then power‑cycle the unit to apply the change.
From: Kunlun Coast JWSK-5 Temperature Humidity Transmitter User Manual