Collihigh JWSK-5 Manuals

ManualLib has 2 documents for the Collihigh JWSK-5: 2 user manuals. Every file can be read online or downloaded as a PDF for free.

User Manual 2

Key facts

Model
JWSK-5
Industry
Industrial
Documents
2
Languages
ZH
Last added
2012-03-14

Start here

Kunlun Coast JWSK-5 Temperature Humidity Transmitter User Manual

Kunlun Coast JWSK-5 Temperature Humidity Transmitter User Manual

User Manual 7 pages · 377 KB · ZH

The JWSK-5 series is an industrial‑grade temperature and humidity transmitter capable of measuring –40 °C to 120 °C and 0 %RH to 100 %RH. It offers multiple analog outputs (0–5 V, 0–10 V, 4–20 mA) and optional RS485 or RS232 network interfaces, with a 128 × 64 LCD display showing temperature, humidity and dew‑point.

The manual covers product overview, technical parameters, physical dimensions and wiring diagrams, step‑by‑step installation for wall‑mount, pipe‑mount and split‑type units, operation of the LCD menu, communication settings (Modbus RTU), maintenance, storage, unpacking inspection, and detailed fault analysis with troubleshooting procedures. This manual is written in Chinese.

Read online

Collihigh JWSK-5 specifications

Power supply (current output type)DC 24V (22V–26V)
Power supply (voltage output type)DC 24V (12V–24V)
Temperature accuracy±0.5 °C (‑20 °C–60 °C)
Humidity accuracy±3 %RH (0 %RH–100 %RH at 25 °C)
Temperature measurement range-40 °C to 120 °C
Humidity measurement range0 %RH to 100 %RH
Analog output options0–5 V, 0–10 V, or 4–20 mA
Network output optionsRS485 or RS232
LCD display resolution0.1 %RH, 0.1 °C
Voltage output load impedance250 Ω

Source: Kunlun Coast JWSK-5 Temperature Humidity Transmitter User Manual

All Collihigh JWSK-5 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

How can I change the transmitter's communication address?

Send a Modbus write command (function 0x06) with the new address, e.g., 0x06 00 03 new_address, then power‑cycle the unit to apply the change.

From: Kunlun Coast JWSK-5 Temperature Humidity Transmitter User Manual

What are the default communication settings for the RS232/RS485 interface?

The default settings are COM1, 9600 baud, 8 data bits, no parity, 1 stop bit, and a 1000 ms polling interval.

From: Kunlun Coast JWSK-5 Temperature Humidity Transmitter User Manual

How should the controller be installed?

Wall‑mount and split‑type units are fixed to the wall with two mounting holes; pipe‑type units are attached with four Ø8 holes on a flange, and the probe is secured with an M22×1.5 thread.

From: ColliHigh JWSK-5 Temperature & Humidity Controller User Manual

How often should the controller be calibrated?

It is recommended to calibrate the controller at least once a year to maintain measurement accuracy.

From: ColliHigh JWSK-5 Temperature & Humidity Controller User Manual