Featured Kaiji manuals

Kaiji JC-1 Apoptosis Detection Kit User Manual
The Kaiji JC-1 Apoptosis Detection Kit is designed to detect changes in mitochondrial transmembrane potential (Δψ) in cells, tissues, or purified mitochondria. It utilizes the JC-1 cationic lipid fluorescent dye, which exists as monomers and polymers depending on membrane potential. In healthy cells with high potential, JC-1 forms red-fluorescing polymers within mitochondria; in apoptotic cells where potential collapses, it releases as green-fluorescing monomers into the cytoplasm. This manual is written in Chinese.
Covers: Kit Description · Components and Storage · Required Instruments · Precautions · Working Solution Preparation · Suspension Cell Protocol

Kaiji One-Step TUNEL Cell Apoptosis Detection Kit Manual
The Kaiji One-Step TUNEL Cell Apoptosis Detection Kit offers a high-sensitivity and rapid method for detecting cell apoptosis by identifying DNA breaks in apoptotic cells. The kit utilizes a biotin-labeled dUTP system amplified by a biotin-streptavidin system for fluorescence detection, suitable for both tissue sections and cell smears. This manual is written in Chinese.
Covers: TUNEL Detection Principle · Kit Components · Storage and Preparation · Sample Preparation · Positive Control Preparation · Labeling and Detection Steps
Latest Kaiji manuals
Kaiji JC-1 Apoptosis Detection Kit User Manual
User Manual 3 pages · 407 KB · ZHThis manual provides instructions for the Kaiji JC-1 Apoptosis Detection Kit, which uses JC-1 dye to assess cell apoptosis by measuring mitochondrial…
Kaiji One-Step TUNEL Cell Apoptosis Detection Kit Manual
User Manual 2 pages · 350 KB · ZHThis manual provides instructions for the Kaiji One-Step TUNEL Cell Apoptosis Detection Kit (KGA7071/72/73) for detecting cell apoptosis in tissue and cell…
Which document do I need?
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Kaiji manuals
What is the recommended cell density for testing?
The manual recommends collecting a cell amount of 1×10^6 per test.
How should JC-1 be stored and handled?
JC-1 must be stored at -20℃ in the dark and used while avoiding light exposure.
What is the principle of the TUNEL detection method?
The method detects DNA breaks in apoptotic cells by connecting biotin-labeled dUTP to the 3'-OH ends of broken DNA using TdT enzyme, followed by fluorescence detection via a biotin-streptavidin system.
From: Kaiji One-Step TUNEL Cell Apoptosis Detection Kit Manual
What samples are suitable for this kit?
The kit is suitable for detecting apoptosis in tissue samples (paraffin-embedded, frozen, and ultra-thin sections) and cell samples (cell smears or coverslips).
From: Kaiji One-Step TUNEL Cell Apoptosis Detection Kit Manual