Zemic H10J Load Cell Application Guideline
This Zemic H10J application guideline covers the installation of H10J load cells and cables for on-board truck and trailer weighing systems. It describes typical applications such as dump bodies, tankers, flat beds and van type superstructures mounted on truck chassis or trailers.
The document explains in-line and outboard mounting styles, accuracy and performance factors, superstructure preparation, frame stiffeners, recess mounting, alignment, mounting structure, and bolting requirements for load cell brackets.
Covers: Introduction · Installation Types · Mounting Styles · Accuracy and Performance · Superstructure Preparation · Frame Stiffeners

Zemic ATEX Load Cell Instruction Manual
This instruction manual from Zemic covers load cells certified for use in potentially explosive atmospheres under ATEX Directive 94/9/EC. It explains product labelling and identification, special conditions for safe use, installation requirements, and care of the load cells.
The document also describes maintenance tools and procedures, repair and warranty terms, and failure analysis with guidance on avoiding misuse. Load cell-specific information is stated to be printed on the calibration certificate.
Covers: Introduction · Product Description · Products Labelling · Product identification and technical Specifications · Special conditions for safe use · Installation
Latest Zemic manuals
Zemic H10J Load Cell Application Guideline
Application Note 8 pages · 986 KB · ENZemic H10J load cell application guideline covering installation types, mounting styles, accuracy, and frame preparation for truck and trailer weighing.
Zemic ATEX Load Cell Instruction Manual
User Manual 7 pages · 743 KB · ENZemic ATEX load cell instruction manual covering certification, safe use, installation, maintenance and failure analysis.
Which document do I need?
Application Note
How to use the product for one specific task, with worked examples.
User Manual
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in Zemic manuals
What are the two basic mounting styles for frame mounted on-board weighing systems?
The in-line mount and the outboard mount.
How much does in-line mounting raise the overall vehicle height?
Approximately 90 mm (3½") unless the frame is recessed.
What ATEX directive are the load cells certified to?
The load cells are certified according to ATEX Directive 94/9/EC.
What should be used when installing load cells in potentially explosive atmospheres?
Use shunt-diode barriers for load cell installation.