Shanghai ShuoZhou Electronics ODMC Air Hammer Control Box Installation and Operating Instructions

ODMC pneumatic percussion hammer is dedicated controller for pneumatic percussion hammer automation control devices , change control system There is a strong immunity system , various parameters are adjustable , controllable pneumatic percussion hammer percussion interval cycle frequency And other parameters , using a programmable controller (PLC) to achieve a combination of hardware such as automatic control , through the process To meet a variety of needs , and its function is greatly improved


Shanghai ShuoZhou Electronics ODMC Air Hammer Control Box Installation and Operating Instructions - cover page
Brand
ShuoZhou Electronics
Category
Air hammer control box
Document type
User Manual
Language
Chinese
Pages
3
File format
PDF
File size
261 KB
Published
30 April, 2014
Updated
25 September, 2023
MD5 checksum
3EC0EC9F2AB724D2E1B8E47322AF77BC

About this manual

The ODMC pneumatic percussion hammer dedicated controller is an automation control device designed for pneumatic percussion hammers. It features a strong immunity system and allows for the adjustment of various parameters, including the percussion interval cycle frequency. The device utilizes a programmable controller (PLC) combined with hardware to achieve automatic control, meeting diverse needs through programming and significantly improving functionality. This manual is written in Chinese.

What's inside

  • Product Overview
  • Technical Parameters
  • Debugging Methods
  • Percussion Interval Adjustment
  • Percussion Width Adjustment
  • Percussion Path Adjustment
  • Key Operation Functions

Specifications

Controlled Pulse Valve Count1-10, 11-20 (arbitrary setting)
Rated Output VoltageAC 220V / DC24V/AC220V
Rated Output Current1A
Output Pulse Interval Range1-999 seconds
Output Pulse Width Range0.1-9.9 seconds
Protection RatingIP65
Operating Temperature-25°C to +55°C

Frequently asked questions

What is the factory default setting for the output pulse interval?

The factory default setting for the output pulse interval is 10 seconds.

What is the factory default setting for the output pulse width?

The factory default setting for the output pulse width is 0.2 seconds.

How do you save the adjusted parameters on the control box?

To save parameters, press the 'Confirm' key once after adjusting the desired value.