Agilent Manuals (Industrial)

Agilent 7500 Series ICP-MS Brochure(1)(1)

The product is an advanced ICP-MS analyzer imported from abroad. It can achieve fast, accurate and multi-element metal analysis, including As, Se, Sb, Hg and other elements.

File format: PDF Size:1374 KB

Agilent 7683B Automatic Liquid Sampler Brochure Manual

Agilent 7683B Automatic Liquid Sampler delivers accurate and reliable results for high-volume drug screenings, pesticides analysis, and other applications. This sampler features a modular design that permits easy inlet maintenance and fast, cost-effective service. It can be used with Agilent 7890A, 6890N, and 6890 Plus GCs.

File format: PDF Size:463 KB

Agilent Food Safety is More Than a Challenge Manual

This PDF file introduces Agilent's technology advantages in food safety analysis, including reliable instrumentation, quality-certified consumables and easy-to-use software

File format: PDF Size:173 KB

Agilent Capillary Electrophoresis System Manual

This document introduces the new features of Agilent capillary electrophoresis system, including high efficiency, rapid analysis, high accuracy, etc. It is suitable for a wide range of applications in many industries, such as drug discovery and development, quality control and ion analysis.

File format: PDF Size:736 KB

Agilent Poroshell 300SB-C18 for Fast High Protein Separation Manual

Poroshell 300SB-C18 is a tool for fast, high-resolution protein separations. It consists of a thin layer of porous silica on a solid core, allowing for protein separation in minutes or seconds with high resolution. Bonded with the patented StableBond C18 phase, it provides reliable separations and unmatched column stability. It can also separate at high temperatures with minimal bleed, resulting in clean MS signals at ultra-high speed. Poroshell 300SB also has low backpressure, enabling separation at very high flow rates. This is a tool to revolutionize proteomics and protein analysis.

File format: PDF Size:8066 KB

Agilent GCxGC Brochure Brief Manual

GC x GC is a powerful gas chromatography technique for analyzing complex mixtures such as petrochemicals, fragrances, and environmental samples. Compared to conventional gas chromatography, GC x GC can improve peak resolution and peak capacity to provide highly detailed sample characterization.

File format: PDF Size:1844 KB

Agilent Remote Advisor Frequently Asked Questions Brochure Brief Manual

Remote Advisor is a remote monitoring and diagnostics solution for instruments that can help customers continuously monitor system health and provide interactive remote diagnostics.

File format: PDF Size:149 KB

Agilent Macroporous Reversed-Phase C18 High-Recovery Protein Fractionation HPLC Column Manual

The document describes Agilent's Macroporous Reversed-Phase C18 High-Recovery Protein Fractionation HPLC Column, which can achieve high protein recovery and fast desalting.

File format: PDF Size:210 KB

Agilent MassHunter Profiling Software for the Agilent 6210 TOF LC/MS Manual

The Agilent MassHunter Profiling software is specifically designed for expression profiling applications such as biomarker discovery. When used with the Agilent 6210 TOF LC/MS, the MassHunter Profiling software clearly identifies statistically meaningful differences between sample groups, allows selection of comparison criteria, and exports profile data for statistical analysis using Agilent's GeneSpring GX software, other database search programs, identification environments, or statistical analysis packages. MassHunter Profiling software also supports additional applications such as pharmaceutical impurity analysis, forensic analysis, environmental analysis, and pesticide analysis. Mass profiling is widely used to compare the expression of peptides, proteins, or metabolites for biomarker discovery in a variety of comparative studies (e.g., healthy versus diseased or drug-treated samples, monitoring disease states). Mass profiling can also be used for other applications, including the detection of pharmaceutical impurities and targeted compounds such as pesticides or drugs of abuse.

File format: PDF Size:265 KB

Agilent GeneSpring MS Product Note Manual

GeneSpring MS is part of the GeneSpring Analysis Platform, an expanding suite of integrated software applications designed to enable systems-level investigation of biological research questions.

File format: PDF Size:598 KB

Agilent Turning Samples into Answers - Agilent 6210 Time-of-Flight LC/MS Manual

The Agilent 6210 Time-of-Flight LC/MS offers exceptional analytical performance, providing greater analytical confidence, resolving complex mixtures, simultaneously identifying high- and low-abundance components, and detecting even low-level components through outstanding sensitivity. It also acquires more information from unknowns with its ultra-fast data acquisition.

File format: PDF Size:499 KB

Agilent Multiple Affinity Removal System Manual

The document describes the features and characteristics of the Agilent Multiple Affinity Removal System. This system allows for the simultaneous removal of multiple high-abundance proteins, enabling easier detection of low-abundance proteins and peptides. It has a larger loading capacity and reusable columns, minimizing sample loss and improving the detection limits of protein separation methods. Additionally, the system minimizes non-specific protein binding without sacrificing efficiency.

File format: PDF Size:425 KB

Agilent Faster easier flexible proteomics solutions Manual

This document introduces the application of Agilent's HPLC-Chip LC/MS product in proteomics research. The product features flexibility, high performance, and reliability, and can address various challenges in protein analysis.

File format: PDF Size:2264 KB

Agilent Refinery Gas Analyzer - Analysis of Hydrocarbons in Refinery Cracked Gas Manual

This document describes a refinery gas analyzer that uses a flame ionization detector (FID) to detect C1 to C7 paraffins and olefins, with a lower detection limit of 20 ppm. The analyzer can be optionally configured with liquid sample valves for the injection of pressurized liquid samples. It is also capable of analyzing trace sulfurs in refinery gas, heavy hydrocarbons, and trace CO. Additionally, it can be customized to perform specific ASTM and ISO tests. The analyzer offers high temperature injection for heavy fractions and can analyze reactor effluent gases using a TCD/TCD/MSD configuration. The entire analysis has a run time of less than 15 minutes.

File format: PDF Size:328 KB

Agilent Fast Natural Gas Analyzer - Simple Analysis of Natural Gas Manual

The document describes the application of a thermal conductivity detector (TCD) to identify air composite (oxygen, nitrogen, and carbon monoxide), methane, carbon dioxide, ethane, propane, isobutane, n-butane, neopentane, isopentane, and n-pentane. It has a lower detection limit of 200 ppm for all components and complies with Gas Processors Association methods 2177 and/or 2261. The analysis time is approximately 15 minutes.

File format: PDF Size:176 KB

Agilent Extended Natural Gas Analyzer - Traditional Extended Hydrocarbon Analysis through C12

This document introduces the features and characteristics of Agilent 325-00 Agilent Extended Natural Gas Analyzer, including the detection limit of C1-C12 n-paraffins to 1 ppm, the detection of air composite, carbon dioxide, C1-C5 paraffins, and the system configuration, analysis time, etc.

File format: PDF Size:1455 KB

Agilent Extended Natural Gas Analyzer - Traditional Extended Hydrocarbon Analysis through C12 with Fixed Gases

This document introduces the technical overview of Agilent Extended Natural Gas Analyzer (Agilent 326-00), including its configuration, detection range, analysis time, etc.

File format: PDF Size:1025 KB

Agilent Monomer Analyzer - Impurities in Polymer-Grade Ethylene Propylene (Application 462B-00)

This document introduces the features of the Agilent Monomer Analyzer (462B-00), including detectable impurities, optional configurations and application scenarios.

File format: PDF Size:167 KB

Agilent Fast Refinery Gas Analyzer - Rapid Analysis of Light Hydrocarbons Fixed Gases in Refinery Cracked Gases

This document introduces the application of Agilent Fast Refinery Gas Analyzer. The instrument uses Flame Ionization Detector (FID) and Thermal Conductivity Detector (TCD) to detect C1 to C7 paraffins and olefins, as well as hydrogen, carbon dioxide, ethane, ethylene, acetylene, hydrogen sulfide, nitrogen, methane, and carbon monoxide. The instrument can also be customized for different analysis requirements.

File format: PDF Size:382 KB

Brands



Products