Verder VA 50 Manuals

ManualLib has 2 documents for the Verder VA 50 (Industrial Supply): 1 user manual, 1 datasheet. Every file can be read online or downloaded as a PDF for free.

User Manual 1Datasheet 1

Key facts

Brand
VERDER
Model
VA 50
Industry
Industrial
Documents
2
Languages
EN · DE
Last added
2026-09-28

Start here

Verder VA 50 Air-Operated Diaphragm Pump User Manual and Parts List

Verder VA 50 Air-Operated Diaphragm Pump User Manual and Parts List

User Manual 36 pages · 912 KB · EN

The VA 50 air‑operated diaphragm pump is intended for professional fluid‑transfer applications. The manual begins with important safety warnings, including pressure limits, hazardous fluid handling, and grounding requirements to prevent injury and equipment damage.

The document then covers installation, operation, maintenance, and troubleshooting procedures, followed by detailed parts listings, torque sequences, technical specifications, performance charts, and warranty information to help users install, operate, and service the pump safely and efficiently.

Read online

Verder VA 50 specifications

Maximum Fluid Working Pressure8.4 bar
Air Pressure Operating Range1.4–8.4 bar
Maximum Air Consumption4.9 N·m³/min
Maximum Free Flow Delivery568 l/min
Maximum Pump Speed145 cpm
Liters per Cycle3.90
Maximum Suction Lift5.48 m (wet or dry)
Maximum Pumpable Solids Size6.3 mm
Weight (Aluminum Pump)26.3 kg
Maximum Operating Temperature65.5 °C

Source: Verder VA 50 Air-Operated Diaphragm Pump User Manual and Parts List

All Verder VA 50 documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What is the maximum fluid working pressure of the VA 50 pump?

The VA 50 pump is rated for a maximum fluid working pressure of 8.4 bar.

From: Verder VA 50 Air-Operated Diaphragm Pump User Manual and Parts List

What is the maximum operating pressure for the pump?

The pump operates at a maximum air pressure of 8.4 bar.

From: VERDER VA50 Pneumatic Diaphragm Pump Datasheet

What is the maximum size of solid particles the pump can handle?

The pump can handle solid particles up to 6.3 mm in size.