Uni-Trend UT513 Insulation Resistance Tester Operating Manual

Uni-Trend UT513 Insulation Resistance Tester Operating Manual

User Manual 33 pages · 572 KB · EN

This manual provides instructions for operating the Uni-Trend UT513 insulation resistance tester. It includes sections on unpacking, safety precautions, meter structure, display, key functions, measurement operations, USB interface, and maintenance. Technical specifications for voltage and insulation resistance measurements are also detailed.

The device is designed for handheld insulation resistance testing and complies with IEC61010 safety standards. It features battery operation with sleep mode, USB connectivity, and a backlit LCD display. Safety warnings and operational cautions are emphasized to prevent electric shock and ensure accurate measurements.

Read online

Uni-Trend UT513 specifications

Safety ComplianceEN 61010-1:2010, Pollution Degree 2, CAT III 600V, double insulation
Battery8 x 1.5V LR14 batteries
Power Adaptor Input230V, 50/60Hz, 75mA
Power Adaptor OutputDC 13.5V, 1100mA
Output Voltages500V, 1000V, 2500V, 5000V
Insulation Resistance Range at 5000V10M ~ 1000G, open circuit voltage DC 5000V
Current ConsumptionMaximum around 1.0A, average around 20mA

Source: Uni-Trend UT513 Insulation Resistance Tester Operating Manual

All Uni-Trend UT513 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What items are included with the UT513?

The package includes the English operating manual, three test leads with alligator clips (black, green and red), eight 1.5V LR14 batteries, a tool box, a USB interface cable, software and optionally a power adaptor.

From: Uni-Trend UT513 Insulation Resistance Tester Operating Manual

What safety category and insulation does the meter comply with?

It complies with EN 61010-1:2010 for pollution degree 2, measurement category CAT III 600V and double insulation.

From: Uni-Trend UT513 Insulation Resistance Tester Operating Manual

What is the battery indicator status when the battery is empty?

The battery indicator shows 10V or less, meaning the battery is empty and the meter cannot guarantee accuracy.

From: Uni-Trend UT513 Insulation Resistance Tester Operating Manual

What safety standard does the UT513 comply with?

The UT513 complies with IEC 61010 safety measurement requirement: in pollution degree 2, overvoltage category (CAT. III 600V) and double insulation.