Thermo Scientific 1300 Series A2 Biological Safety Cabinet User Manual
This manual provides instructions for the Thermo Scientific 1300 Series A2 Class II, Type A2 biological safety cabinet. It covers safety systems, including negative pressure air systems and HEPA filters, as well as the digital airflow verification (DAVe) system that monitors inflow and downflow velocities. The document details the intended use for protecting users, samples, and the environment in clinical laboratories.
Read onlineThermo Scientific 1300 Series A2 specifications
| Class | Class II, Type A2 |
|---|---|
| Voltage | 230 V |
| Dimensions (Model 1344) | 1.2 m |
| Dimensions (Model 1349) | 1.8 m |
| Stand Height (Optional) | 750 mm to 950 mm |
| Stand Height (Fixed) | 864 mm |
Source: Thermo Scientific 1300 Series A2 Biological Safety Cabinet User Manual
All Thermo Scientific 1300 Series A2 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What standards does the 1300 Series A2 comply with?
The six-foot model is certified in accordance to YY 0569-2005, and the four-foot model is designed in accordance to SFDA standards.
From: Thermo Scientific 1300 Series A2 Biological Safety Cabinet User Manual
Can the UV light be used while the front window is open?
No, the optional UV light will not turn on if the front window is open to protect from UV radiation.
From: Thermo Scientific 1300 Series A2 Biological Safety Cabinet User Manual
What safety systems are included in the 1300 Series A2?
The cabinet includes a negative pressure air system, HEPA filters for downflow and exhaust, Digital Airflow Verification (DAVe), and window position monitoring.
From: Thermo Scientific 1300 Series A2 Biological Safety Cabinet Operating Manual
When will the optional UV light turn on?
The optional UV light will not turn on if the front window is open; it requires the window to be closed and locked.
From: Thermo Scientific 1300 Series A2 Biological Safety Cabinet Operating Manual
What technology does the cabinet use for airflow compensation?
It uses SmartFlow™ technology, an automatic airflow compensation system that adjusts motor speed as filters load.
From: Thermo Scientific 1300 Series A2 Biological Safety Cabinet Operating Manual
Who should perform internal adjustments and maintenance?
All internal adjustments and maintenance must be performed by qualified service personnel.