Teledyne LeCroy HDO6000/HDO6000A High Definition Oscilloscopes Operator's Manual
This operator's manual covers the operation and maintenance of all instruments in the Teledyne LeCroy MAUI HDO6000 series of High Definition Oscilloscopes, with the HDO6000A shown in the illustrations. It explains the front, side and back of the instrument, front panel controls, signal interfaces, probes, powering on and off, software activation and connecting to other devices and systems.
The manual then walks through the MAUI touch screen interface and working with traces, followed by chapters on acquisition, timebase, triggering, display, cursors, measurements, math functions, memory, analysis tools such as WaveScan, PASS/FAIL testing and the spectrum analyzer, saving and recalling data, utilities, and maintenance procedures including restart, restore default setup, touch screen calibration and firmware updates.
Teledyne LeCroy HDO6000 specifications
| Operating temperature | 5 °C to 40 °C |
|---|---|
| Operating humidity | Maximum 90% RH up to 31 °C, decreasing linearly to 50% RH at 40 °C |
| Operating altitude | Up to 10,000 ft (3,048 m) at or below 30 °C |
| AC power | 100-240 Vrms (±10%) at 50/60 Hz (±5%); 100-120 Vrms (±10%) at 400 Hz (±5%) |
| Maximum power consumption | 320 W (320 VA) |
| Nominal power consumption | 200 W (200 VA) |
| Standby power consumption | 4 W |
| Maximum input voltage (50 Ω coupling) | ≤ 5 Vrms |
| Maximum input voltage (1 MΩ coupling) | ≤ 400 Vpk max (Peak AC ≤ 10 kHz + DC), derating above 10 kHz |
Source: Teledyne LeCroy HDO6000/HDO6000A High Definition Oscilloscopes Operator's Manual
All Teledyne LeCroy HDO6000 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
Does the HDO6000 require manual line voltage selection?
No. The instrument automatically adapts to the line voltage; manual voltage selection is not required.
From: Teledyne LeCroy HDO6000/HDO6000A High Definition Oscilloscopes Operator's Manual
How should I clean the oscilloscope?
Clean only the exterior using a soft cloth moistened with water or an isopropyl alcohol solution, and unplug the power cord before cleaning. Do not use harsh chemicals or attempt to clean internal parts.
From: Teledyne LeCroy HDO6000/HDO6000A High Definition Oscilloscopes Operator's Manual
What oscilloscope does this manual cover?
It covers the HDO6000 high definition oscilloscopes.
From: Teledyne LeCroy HDO6000 High Definition Oscilloscope Operator's Manual
When was this manual published?
It was published in November 2013.
From: Teledyne LeCroy HDO6000 High Definition Oscilloscope Operator's Manual