User Manual 137 pages · 5.1 MB · EN

The TECO L510 Series is a microprocessor-controlled IGBT drive inverter motor speed regulator. The manual covers 100 V, 200 V and 400 V models, with 0.2~0.75kW (0.25~1HP), 0.2~2.2kW (0.25~3HP) and 0.75~2.2kW (1~3HP) capacity ranges respectively.

It explains safety precautions, part number definition, environment and installation, wiring, specifications, standard wiring, terminal descriptions and dimensions. It also covers keypad operation, programmable parameter groups, troubleshooting, maintenance, peripheral components and MODBUS communication.

Read online

TECO L510 Series specifications

Motor capacity, 100 V models0.2~0.75kW (0.25~1HP)
Motor capacity, 200 V models0.2~2.2kW (0.25~3HP)
Motor capacity, 400 V models0.75~2.2kW (1~3HP)
Supply voltage, single-phase 100 V models1ph, 100~120V +10%/-15%
Circuit capability5,000 rms symmetrical amperes maximum
Rated input frequency50/60Hz

Source: TECO L510 Series Frequency Inverter Operating Manual

All TECO L510 Series documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

How long should I wait before opening the inverter after removing power?

Wait five minutes, because the DC link capacitors remain charged after power is removed.

From: TECO L510 Series Frequency Inverter Operating Manual

What ambient temperature range is allowed?

The manual states -10 to 40°C, with -10 to 50°C for models with a fan.

From: TECO L510 Series Frequency Inverter Operating Manual

How long must I wait after switching off the power before servicing the L510?

Wait 5 minutes after the power is removed; the DC capacitors need this time to discharge before disassembly or inspection.

From: TECO L510 Series AC Motor Drive User Manual

What is the protection rating of the L510 drive?

The drive has an IP20 protection rating.

From: TECO L510 Series AC Motor Drive User Manual