Sysmex XN-1000 Manuals

ManualLib has 5 documents for the Sysmex XN-1000 (Other): 4 user manuals, 1 product leaflet. Every file can be read online or downloaded as a PDF for free.

User Manual 4Product Leaflet 1

Key facts

Brand
Sysmex
Model
XN-1000
Category
Other
Documents
5
Languages
ZH · ES · EN
Last added
2026-11-07

Start here

Sysmex XN-1000 Automated Hematology Analyzer Instructions for Use

Sysmex XN-1000 Automated Hematology Analyzer Instructions for Use

User Manual 20 pages · 684 KB · EN

This manual from Sysmex covers the XN series automated hematology analyzer, including the XN-1000. It says the system is an automated hematology analyzer for in vitro diagnostic use in clinical laboratories and that only human blood, human body fluids, or control blood should be run.

The manual includes chapters on safety, part names and functions, preparation, quality control, sample analysis, calibration, maintenance, troubleshooting, and technical information. It describes analysis by electrical impedance, laser light scattering, and dye bonding, and it notes that data should not replace professional judgment in diagnosis or patient therapy monitoring.

Read online

Sysmex XN-1000 specifications

Sample Processing Rate100 samples/h
Sampler Capacity5 racks
Optional UpgradeXN-20 CBC analyzer with WPC channel

Source: Sysmex XN-1000 Hematology Analyzer Operator's Manual

All Sysmex XN-1000 documents by type

Questions answered in these manuals

What is the sample processing capacity of the XN-1000?

The XN-1000 can process 100 samples per hour.

From: Sysmex XN-1000 Hematology Analyzer Operator's Manual

Can the XN-1000 be networked with other systems?

Yes, it can be networked with other XN systems at different locations for flexible deployment.

From: Sysmex XN-1000 Hematology Analyzer Operator's Manual

What is the sample processing capacity of the XN-1000?

The analyzer processes 100 samples per hour.

From: Sysmex XN-1000 Hematology Analyzer Product Leaflet

How many racks can the XN-1000 load at once?

It has a capacity to load up to 5 racks.

From: Sysmex XN-1000 Hematology Analyzer Product Leaflet

What does a POSITIVE IP Message indicate?

It indicates the possibility of sample abnormality and requires a review process by laboratory personnel.

From: Sysmex xn 1000 Flagging Interpretation Guide

What should be done if dashes appear in place of data on a scattergram?

Perform a manual differential according to your laboratory’s policy.

From: Sysmex xn 1000 Flagging Interpretation Guide