Sysmex XN-530 Manuals

ManualLib has 2 documents for the Sysmex XN-530: 1 user manual, 1 quick start guide. Every file can be read online or downloaded as a PDF for free.

User Manual 1Quick Start Guide 1

Key facts

Brand
Sysmex
Model
XN-530
Documents
2
Languages
EN
Last added
2023-10-16

Start here

Sysmex XN-530 Automated Hematology Analyzer Quick Guide

Sysmex XN-530 Automated Hematology Analyzer Quick Guide

Quick Start Guide 16 pages · 2.1 MB · EN

This document serves as a quick guide for the Sysmex XN-530 Automated Hematology Analyzer. It provides an overview of the instrument's front panel components, including the mode switch, start switch, monitor, and on-screen display operation buttons. The guide details status indications such as Ready, Analyzing, Error, and Shutdown states.

Read online

Sysmex XN-530 specifications

Dimensions (Analyzer, XN-530)Approx. 450 W × 660 D × 450 H mm
Weight (Analyzer, XN-530)Approx. 53 kg
Electrical voltage100 to 240 V AC
Power consumption (XN-530)250 VA
Noise level60 dB or less
Throughput (Whole Blood mode, CBC)≈ 60 samples/hour (≈ 70 samples/hour*1)
Laser classClass I (IEC60825‑1:2007)

Source: Sysmex XN-530/XN-430/XN-330 Hematology Analyzer General Information Manual

All Sysmex XN-530 documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Quick Start Guide 1

The shortest path to a working setup, usually only a few pages.

Questions answered in these manuals

What is the intended use of the Sysmex XN‑L analyzer?

It is a quantitative multi‑parameter automated hematology analyzer intended for in‑vitro diagnostic use in clinical laboratory screening.

From: Sysmex XN-530/XN-430/XN-330 Hematology Analyzer General Information Manual

What are the power requirements for the analyzer?

The analyzer operates on 100 to 240 V AC, 50/60 Hz, with a power consumption of 250 VA for the XN‑530 model and 235 VA for the XN‑430/XN‑330 models.

From: Sysmex XN-530/XN-430/XN-330 Hematology Analyzer General Information Manual

What are the required sample volumes for different tube types?

Regular tubes require 1 mL, RBT tubes require 250 µL, Micro Collection Tubes require 300 µL, and Open Tube requires 140 µL.

From: Sysmex XN-530 Automated Hematology Analyzer Quick Guide

How long should QC material be brought to room temperature?

The QC material must be brought to room temperature for 15 minutes before processing.

From: Sysmex XN-530 Automated Hematology Analyzer Quick Guide