Key facts
- Brand
- Rosemount
- Model
- 5081
- Category
- Industrial Supply
- Industry
- Industrial
- Documents
- 2
- Languages
- EN
- Last added
- 2026-10-17
Start here

Rosemount 5081 Explosion-Proof Single-Input Intelligent Transmitter Quick Start Guide
This document serves as a Quick Start Guide for the Rosemount 5081 Explosion-Proof, Single-Input Intelligent Transmitter. It outlines essential instructions for installation, operation, and maintenance, including safety warnings and product certifications. The guide emphasizes the importance of adhering to proper installation procedures to ensure safe operation and warranty validity.
Read onlineRosemount 5081 specifications
| Minimum supply voltage at the transmitter terminals | 12.0 Vdc |
|---|---|
| Maximum power supply voltage | 42.0 Vdc |
| Maximum power supply voltage for intrinsically safe installations | 30.0 Vdc |
| Minimum load for digital communications | 250 Ohms |
Source: Rosemount 5081 Explosion-Proof Single-Input Intelligent Transmitter Quick Start Guide
All Rosemount 5081 documents by type
The shortest path to a working setup, usually only a few pages.
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the minimum supply voltage required at the transmitter terminals?
The minimum supply voltage required at the transmitter terminals is 12.0 Vdc.
From: Rosemount 5081 Explosion-Proof Single-Input Intelligent Transmitter Quick Start Guide
What is the maximum power supply voltage for intrinsically safe installations?
The maximum power supply voltage for intrinsically safe installations is 30.0 Vdc.
From: Rosemount 5081 Explosion-Proof Single-Input Intelligent Transmitter Quick Start Guide
How many wires does the transmitter use for power and signal?
It uses a two‑wire loop delivering a 4‑20 mA current signal with a superimposed HART digital signal.
From: Rosemount 5081-P Two-Wire pH/ORP Transmitter User Manual
What hazardous‑location approvals does the transmitter have?
The transmitter has a robust Type 4X enclosure and an intrinsically safe design for use in hazardous environments when proper safety barriers are applied.
From: Rosemount 5081-P Two-Wire pH/ORP Transmitter User Manual