Qingzhi ZWD414B/D415/D416/D433B/D432B/D433C Comprehensive Power Transmitter User Manual
This manual provides usage instructions for the Qingzhi ZWD series comprehensive power transmitters, covering models ZWD414B, ZWD415, ZWD416, ZWD433B, ZWD432B, and ZWD433C. It details product selection based on measurement parameters such as voltage, current, power, and frequency for single-phase and three-phase applications. This manual is written in Chinese.
Read onlineQingzhi ZWD414B specifications
| Voltage measurement range | 10–500 V |
|---|---|
| Current measurement range (single‑phase) | 0.02–20 A |
| Voltage input impedance | >2 MΩ |
| Current input impedance | <10 mΩ |
| Power supply | AC 85–265 V, 45–65 Hz; DC 125–250 V |
| Communication protocol | MODBUS RTU over RS‑485/232 |
| Display update rate | ≈2 times/second |
| Conversion rate | ≈8000 times/second |
| Dimensions (W×H×D) | 110 mm × 74 mm × 63 mm |
| Weight | ≈400 g |
Source: Qingzhi ZWD414B/ZWD433B Comprehensive Power Transducer User Manual
All Qingzhi ZWD414B documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What power supply voltages are required for operation?
The transducer can be powered from AC 85–265 V at 45–65 Hz or from DC 125–250 V.
From: Qingzhi ZWD414B/ZWD433B Comprehensive Power Transducer User Manual
What happens if no parameter changes are saved within 15 seconds?
If there is no operation for 15 seconds, the device automatically exits the setting mode and does not save the changes.
From: Qingzhi ZWD414B/ZWD433B Comprehensive Power Transducer User Manual
What is the measurement accuracy for active power?
The basic error is ±(0.4% reading + 0.1% range)when PF=1.0.
From: Qingzhi ZWD414B/D415/D416/D433B/D432B/D433C Comprehensive Power Transmitter User Manual
How do I handle communication failures?
Check the RS485 converter connection and verify the communication parameter settings.
From: Qingzhi ZWD414B/D415/D416/D433B/D432B/D433C Comprehensive Power Transmitter User Manual
What is the measurement range for AC voltage?
The measurement range for AC voltage is from 10V to 500V.
From: ZWD414B/D415/D416/D433B/D432B/D433C Comprehensive Power Transmitter User Manual
What is the operating frequency range for AC signals?
The instrument measures AC signals within a frequency range of 45 to 65 Hz.
From: ZWD414B/D415/D416/D433B/D432B/D433C Comprehensive Power Transmitter User Manual