Key facts
- Brand
- Qingzhi
- Model
- D416
- Category
- Other Electronics
- Industry
- Industrial
- Documents
- 2
- Languages
- ZH
- Last added
- 2023-03-27
Start here

Qingzhi ZWD414B/D415/D416/D433B/D432B/D433C Comprehensive Power Transmitter User Manual
This manual provides usage instructions for the Qingzhi ZWD series comprehensive power transmitters, covering models ZWD414B, ZWD415, ZWD416, ZWD433B, ZWD432B, and ZWD433C. It details product selection based on measurement parameters such as voltage, current, power, and frequency for single-phase and three-phase applications. This manual is written in Chinese.
Read onlineQingzhi D416 specifications
| Voltage Range | 10-500V |
|---|---|
| Current Range | 0.02-20A |
| Frequency Range | 45-65Hz |
| Power Supply | AC 85-265V, DC 125-250V |
| Communication Protocol | RS-485/232, MODBUS |
| Weight | Approx. 400g |
Source: Qingzhi ZWD414B/D415/D416/D433B/D432B/D433C Comprehensive Power Transmitter User Manual
All Qingzhi D416 documents by type
Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.
Questions answered in these manuals
What is the measurement accuracy for active power?
The basic error is ±(0.4% reading + 0.1% range)when PF=1.0.
From: Qingzhi ZWD414B/D415/D416/D433B/D432B/D433C Comprehensive Power Transmitter User Manual
How do I handle communication failures?
Check the RS485 converter connection and verify the communication parameter settings.
From: Qingzhi ZWD414B/D415/D416/D433B/D432B/D433C Comprehensive Power Transmitter User Manual
What is the measurement range for AC voltage?
The measurement range for AC voltage is from 10V to 500V.
From: ZWD414B/D415/D416/D433B/D432B/D433C Comprehensive Power Transmitter User Manual
What is the operating frequency range for AC signals?
The instrument measures AC signals within a frequency range of 45 to 65 Hz.
From: ZWD414B/D415/D416/D433B/D432B/D433C Comprehensive Power Transmitter User Manual