PR 5334 Programmable Two-Wire Transmitter User Manual

PR 5334 Programmable Two-Wire Transmitter User Manual

User Manual 21 pages · 1.2 MB · PT

This document is the user manual for the PR 5334 programmable two-wire transmitter, designed for industrial and factory automation. It includes installation instructions, programming details, and technical specifications. The device supports temperature measurement with TC sensors, signal amplification to 4–20 mA, and features like galvanic isolation, configurable sensor error detection, and multiple communication interfaces including Modbus and Bluetooth. It is certified for hazardous areas and meets international standards including ATEX and IECEx.

The manual provides wiring diagrams, mechanical specifications, and programming via Loop Link. It also includes installation drawings for ATEX, IECEx, and INMETRO compliance, along with environmental and electrical specifications for operation in harsh conditions. This manual is written in Portuguese.

Read online

PR 5334 specifications

Operating Temperature-40°C to +85°C
Calibration Temperature20...28°C
Humidity< 95% RH (non-cond.)
IP Rating (Enclosed / Terminal)IP68 / IP00
DimensionsØ 44 x 20,2 mm
Weight50 g
Max Wire Size1 x 1.5 mm² flexible wire
Terminal Torque0.4 Nm
Power Supply (5334A3B)7.2...35 VDC
Power Dissipation (5334A3B)25 mW...0.8 W
Isolation Voltage (Test / Operation)1.5 kVAC / 50 VAC
Warm-up Time5 min
Signal-to-Noise RatioMin. 60 dB
Response Time (Programmable)1...60 s
EEPROM Error Check Time< 3.5 s
Input Signal Dynamic Range18 bit
Output Signal Dynamic Range16 bit
Voltage Drift< 0.005% of span / VDC
Input Type (TC)E, J, K, L, N, T, U
Input Type (TC High Temp)B, R, S, W3, W5, Lr
Accuracy (TC E, J, K, L, N, T, U)≤ ±1°C
Accuracy (TC B, R, S, W3, W5, Lr)≤ ±2°C
EMC Immunity (General)< ±0.5% of span
EMC Immunity (Extended NAMUR NE21)< ±1% of span

Source: PR 5334 Programmable Two-Wire Transmitter User Manual

All PR 5334 documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the operating temperature range of the PR 5334?

The operating temperature range is -40°C to +85°C.

From: PR 5334 Programmable Two-Wire Transmitter User Manual

What communication interfaces does the PR 5334 support?

The PR 5334 supports Modbus and Bluetooth for communication, and can be configured via push-buttons with a built-in display.

From: PR 5334 Programmable Two-Wire Transmitter User Manual

What temperature range can the 5334A measure?

It measures temperatures from –40 °C to +85 °C.

From: PR Electronics 5334A 2‑Wire Programmable Transmitter Manual

What supply voltage does the 5334A require?

The transmitter operates from a 7.2 V to 35 V DC supply.

From: PR Electronics 5334A 2‑Wire Programmable Transmitter Manual