Novotechnik P2500 Manuals

ManualLib has 2 documents for the Novotechnik P2500: 1 user manual, 1 datasheet. Every file can be read online or downloaded as a PDF for free.

User Manual 1Datasheet 1

Key facts

Model
P2500
Documents
2
Languages
ZH
Last added
2012-04-12

Start here

P2500 Series Angle Sensor User Manual

P2500 Series Angle Sensor User Manual

User Manual 2 pages · 188 KB · ZH

The P2500 series angle sensor is a compact, high‑performance potentiometer‑type sensor with a metal housing, spherical bearings, conductive plastic substrate, and elastic‑damped brush. It offers excellent linearity (≤0.2 %), high resolution (better than 0.01°), and can operate at speeds up to 10 000 rpm with unlimited continuous rotation.

The manual lists mechanical dimensions, installation using three Z1‑11 clamps, electrical parameters such as resistance values (1 kΩ, 2 kΩ, 5 kΩ), voltage range up to 42 V, and environmental limits including a temperature range of –40 °C to +100 °C and IP40 protection. Ordering information and optional accessories are also provided. This manual is written in Chinese.

Read online

Novotechnik P2500 specifications

Operating temperature range-40 °C to 185 °C
IP protection ratingIP40
Maximum working voltage42 V
Maximum brush current10 mA
Standard resistance values5.0 kΩ, 1.8 kΩ
Static and dynamic axial load15 N
Torque0.1 N·cm

Source: SP2500 Series Sensor Datasheet

All Novotechnik P2500 documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Datasheet 1

Ratings, dimensions and ordering codes, for selection and design work.

Questions answered in these manuals

What temperature range can the P2500 sensor operate in?

It operates from –40 °C to +100 °C.

From: P2500 Series Angle Sensor User Manual

What is the static or dynamic load capacity of the sensor?

The sensor can handle a static or dynamic load of 15 N.

From: P2500 Series Angle Sensor User Manual

What is the operating temperature range of the SP2500 sensor?

The sensor operates from –40 °C up to 185 °C.

From: SP2500 Series Sensor Datasheet

What IP protection rating does the SP2500 sensor have?

It has an IP40 protection rating.

From: SP2500 Series Sensor Datasheet