MOTAK MR4/MR6/MR10 Gas Range Owner's Manual

MOTAK MR4/MR6/MR10 Gas Range Owner's Manual

User Manual 16 pages · 666 KB · EN

This manual provides instructions for the MOTAK MR4, MR6, and MR10 series of commercial gas ranges equipped with griddles. It covers essential safety precautions, installation requirements including gas pressure settings, and operational guidelines for the burners and ovens.

The document details routine inspection, cleaning, and maintenance procedures to ensure reliable operation. It also includes a troubleshooting section and specific fire safety warnings, emphasizing that the equipment must be installed by a qualified professional in accordance with local codes.

Read online

MOTAK MR6 specifications

Dimensions (MR4)24" X 32.5" X 24.75"
Dimensions (MR6, MR6-G24)36" X 32.5" X 24.75"
Dimensions (MR10, MR10-G24)60" X 32.5" X 24.75"
Oven Capacity (MR4)20.5"W X 26"D X 14"H
Oven BTU (All Models)30,000 BTU
Burner BTU (MR4)4 x 30,000 BTU
Burner BTU (MR6)6 X 30,000 BTU
Burner BTU (MR10)10 X 20,000 BTU
Gas Pressure (Natural)4.0" W/C
Gas Pressure (LPG)10.0" W/C

Source: MOTAK MR4/MR6/MR10 Gas Range Owner's Manual

All MOTAK MR6 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What are the gas pressure settings for this range?

The factory set gas pressure is 4" Water Column for Natural Gas and 10" Water Column for Propane Gas.

From: MOTAK MR4/MR6/MR10 Gas Range Owner's Manual

Can this appliance be used in residential applications?

No, this appliance is not suitable for installation in a non-commercial or residential application.

From: MOTAK MR4/MR6/MR10 Gas Range Owner's Manual

Can this appliance be used in residential applications?

No, the appliance is not suitable for installation in non-commercial or residential applications.

From: MOTAK MR4-C-S MR6-G24-C-S MR6-C-S MR10-G24-C-S MR10-C-S MR10-RGB24-C-S gas ranges user manual

What compound should be used for pipe threading?

Use a compound resistant to liquefied petroleum gas; do not use Teflon tape.

From: MOTAK MR4-C-S MR6-G24-C-S MR6-C-S MR10-G24-C-S MR10-C-S MR10-RGB24-C-S gas ranges user manual