This manual contains important information regarding your MOTAK unit. Please read the manual thoroughly prior to equipment set-up, operation and maintenance. Failure to comply with regular maintenance guidelines outlined in the manual may void the warranty. Improper installation, adjustment, alteration, service or maintenance can cause property damage, injury or death. Read this manual thoroughly before installing or servicing this equipment. MUST READ!
This manual provides instructions for the MOTAK MR4, MR6, and MR10 series of commercial gas ranges equipped with griddles. It covers essential safety precautions, installation requirements including gas pressure settings, and operational guidelines for the burners and ovens.
The document details routine inspection, cleaning, and maintenance procedures to ensure reliable operation. It also includes a troubleshooting section and specific fire safety warnings, emphasizing that the equipment must be installed by a qualified professional in accordance with local codes.
| Dimensions (MR4) | 24" X 32.5" X 24.75" |
|---|---|
| Dimensions (MR6, MR6-G24) | 36" X 32.5" X 24.75" |
| Dimensions (MR10, MR10-G24) | 60" X 32.5" X 24.75" |
| Oven Capacity (MR4) | 20.5"W X 26"D X 14"H |
| Oven BTU (All Models) | 30,000 BTU |
| Burner BTU (MR4) | 4 x 30,000 BTU |
| Burner BTU (MR6) | 6 X 30,000 BTU |
| Burner BTU (MR10) | 10 X 20,000 BTU |
| Gas Pressure (Natural) | 4.0" W/C |
| Gas Pressure (LPG) | 10.0" W/C |
The factory set gas pressure is 4" Water Column for Natural Gas and 10" Water Column for Propane Gas.
No, this appliance is not suitable for installation in a non-commercial or residential application.
Installation and maintenance must be performed by a qualified installer or trained and qualified person.