User Manual 240 pages · 5.5 MB · ZH

This manual covers the configuration and usage of the Micro Motion 2700 Foundation Fieldbus Transmitter. It details procedures for startup, including power-up and functional block channel allocation. The guide also explains how to configure cumulative function blocks, pressure compensation, and temperature compensation. This manual is written in Chinese.

Read online

Micro Motion 2700 specifications

Operating temperature range-40 °C to 60 °C
Storage temperature range-40 °C to 60 °C
Relative humidity range5 % to 95 % RH
Enclosure protection ratingIP69K (NEMA 4X)
Maximum safe voltage (intrinsically safe)< 30 VDC
Maximum safe current (intrinsically safe)< 300 mA (4‑20 mA) / < 100 mA (frequency/discrete)

Source: Micro Motion 1700 and 2700 Transmitter Installation Manual

All Micro Motion 2700 documents by type

User Manual 1

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Installation Guide 1

Mounting, wiring and first power-up. Read it before the hardware goes in.

Questions answered in these manuals

What firmware version is required for the procedures in this manual?

The procedures are based on transmitter firmware version 7.0 or higher.

From: Micro Motion 2700 Foundation Fieldbus Transmitter Configuration and User Manual

What should be done if the Smart Meter Online Self-Check fails twice?

If the instrument fails the second test, the flow tube may be damaged and should be physically inspected.

From: Micro Motion 2700 Foundation Fieldbus Transmitter Configuration and User Manual

What safety certifications does the Micro Motion 1700/2700 transmitter have?

The transmitter complies with all applicable European directives, has ATEX and IECEx documentation, and is certified by FISCO or FNICO for intrinsically safe use.

From: Micro Motion 1700 and 2700 Transmitter Installation Manual

What are the environmental temperature limits for the 1700 and 2700 transmitters?

The devices operate from –40 °C to 60 °C and can be stored within the same temperature range.