Liquidynamics LD250 Electronic Digital Meter Instruction & Parts Manual

Liquidynamics LD250 Electronic Digital Meter Instruction & Parts Manual

User Manual 13 pages · 813 KB · EN

This manual provides instructions for installing, operating, calibrating, and maintaining the Liquidynamics LD250 electronic digital meter. It explains how to reset batch and cumulative totals, configure units of measure, and perform in-field calibration. The meter uses oval gear technology to measure fluid flow with high accuracy and features an LCD display with multiple total registers. It is designed for use with clean fluids such as engine oil, hydraulic fluid, and antifreeze, and is rated for a maximum operating pressure of 1,000 PSI.

The manual includes safety warnings, technical specifications, troubleshooting tips, and maintenance procedures such as battery replacement and cleaning the measurement chamber. The device is field-replaceable and can be installed in any orientation with ½” NPTF threaded connections.

Read online

Liquidynamics LD250 specifications

Measurement SystemOval Gears
Resolution (Nominal)0.0053 quarts/pulse
Flow Rate Range0.25 to 8 GPM
Operating Pressure, Max.1,000 PSI
Burst Pressure2,900 PSI
Storage Temperature Range-4° F – 158° F
Storage Maximum Humidity95% Relative Humidity, Non Condensing
Operating Temperature Range14° F – 122° F
Pressure Drop @ 4 GPM, SAE 10W @ 68 ° F5 PSI
Allowable Viscosity Range5 – 5000 cps
Accuracy (from 1 – 4 GPM)+/- 1% after Calibration
Reproducibility (typical)+/- 0.3%
Display ScreenLCD w/ 5 digit Batch Total, 6 digit Cumulative Total
Power Supply2 ea. 1.5 V Alkaline batteries, size AAA
Battery Life18 – 36 Months
Weight1.1 lb
Reed Switch Max Current100 mA
Ingress Protection RatingIP65

Source: Liquidynamics LD250 Electronic Digital Meter Instruction & Parts Manual

All Liquidynamics LD250 documents by type

User Manual 2

Day-to-day operation, settings and troubleshooting. Start here if the product is already set up.

Questions answered in these manuals

What is the maximum operating pressure of the LD250 meter?

The maximum operating pressure is 1,000 PSI.

From: Liquidynamics LD250 Electronic Digital Meter Instruction & Parts Manual

What fluids is the LD250 meter designed to measure?

It is designed for use with clean fluids such as engine oil, hydraulic fluid, transmission fluid, and antifreeze.

From: Liquidynamics LD250 Electronic Digital Meter Instruction & Parts Manual

What fluids is the LD250 meter intended for?

The meter is intended for use with clean fluids such as engine oil, gear oil, hydraulic fluid, transmission fluid, and 100% antifreeze.

From: Liquidynamics LD250 Electronic Digital Meter Instruction & Parts Manual

What is the maximum working pressure of the meter?

The meter has a maximum working pressure of 1,000 PSI.

From: Liquidynamics LD250 Electronic Digital Meter Instruction & Parts Manual